NCCER Electrical Practice Exam 2027: Questions & Answers (Free Study Guide)

ENGI100 Engineering — exam and revision material · Other

Updated today

Engineering exam material, 7 pages. Originally published on StudyMerit.

Pages
7
Academic year
2025/2026
Language
English

What’s included

Preview 3 of 7 pages

See the first 3 pages exactly as they appear in the document.

Read page 1 as text

NCCER ELECTRICAL TEST Students also studied Science Engineering Electrical Engineering Save NCCER ELECTRICAL Teacher 139 terms SimplyFTW_ Preview Electrical NCCER test 88 terms jacewilliams2003 Preview The electrical NCCER test Teacher 289 terms fpgoodwin62 Preview Electric 354 term Jim Practice questions for this set Learn 1 / 7 Study with Learn The equipment grounding conductor is used to interconnect and bond: The NEC recommends maintaining voltage within a 3% drop. If a branch circuit operates at 240 volts AC. What is the minimum circuit operating volt? 232 What is the name of the connecting device shown in the diagram? Split-bolt The volt amperes in an AC circuit is the same as Apparent power Choose an answer 1 Current- carrying metal parts 2 High- voltage conductors 3 Insulated electrical components 4 Non- current- carrying metal parts Don't know?

Read page 2 as text

What is the voltage drop for a #8 (16.510 cmil) copper wire at 120v. 215 feet one way and a load of 39amps? 10.5 If a voltage source of a circuit provides 240 volts and there are 5 ohms of resistance, how much current is in the circuit? 48 amps What should be done to change rotation of a 3 phase motor? Swap any 2 T leads What instrument is used to measure current? Ammeter Which plan indicates the location of structures and equipment on a property? Site Generally , the most ideal conductor is made of: Copper What is the standard size system used in the united states? AWG What is insulating tape? Non-Conductive adhesive tape Which of these is used as a guide to assist cables entering a conduit? Piston Which of the following is not a reason why electrical systems must be grounded? Limit the potential between ungrounded conductors What type of conduit body is characterized by a threaded straight hub on each end? C A megger will be used to check an in-service cable. The Electrician MUST be sure that the circuit is: De-energized and locked tagged out, and tested Rubber gloves MUST be electrically tested at MAXIMUM intervals of: 6 months A dangerously high voltage is produced when someone opens the secondary circuit of a: Current transformer Which choice best describes the two types of pushbutton operators typically used in motor controls Open and closed In the event of an emergency where the lockout/ tagout device is left secured, who can remove the lockout/tagout device? Authorized supervisor A drawing showing a point A to point B hookup of conductors is called a: Wiring diagram

Read page 3 as text

A NEMA type___ enclosure is both watertight and corrosion- resistant. 4X What's the MAIN characteristic of a confined space? Limited access and egress Which of the following BEST describes where the type and size of overcurrent protection is found? Panelboard schedule A Type "X" conduit body has how many conduit entries 4 What test equipment can be used to test the condition of insulation in electrical apparatus? Megohmmeter The opposing force to a flow of alternating current is called: Reactance That is a trapeze type support Two threaded rods supporting a channel or strut The opposition to current flow referred to as: Resistance The type of mounting used for lighting fixtures is indicated in the: Electrical drawings Verifying the presence or absence of voltage should be performed only by: Qualified individuals What is shown on a sectional drawing? Cutaway view of a building A conductor with 220 mils of insulation would have insulation thickness of: 0.22'' The recommended method of attaching self- regulating heating cables to pipes is by using: Fiberglass tape An auxiliary holding contact ( seal- in) on a typically NEMA starter is indicated by the terminal marking: A1 & A2* When is it required that conductors be derated? When there are four or more current- carrying conductors in a conduit The conductors used to connect the system grounded conductor or the equipment to a grounding electrode or to a point on the grounding: Electrode conductor The equipment grounding conductor is used to interconnect and bond: Non- current- carrying metal parts The ungrounded conductor of a 240/120 three phase Delta 4 wire system that has the higher voltage to ground MUST be identified with the color: Orange