Skip to content
CramShare
PremiumPractice exam

Icc U2 Ust Decommissioning Exam (2024/2025) | Questions Withanswers

HEAL100 Health Care — exam and revision material · Other

Updated today

Health Care exam material, 73 pages. Originally published on StudyMerit.

Pages
73
Academic year
2025/2026
Language
English

What’s included

Preview 3 of 73 pages

See the first 3 pages exactly as they appear in the document.

Read page 1 as text

ICC U2 UST Decommissioning Exam Questions 2025/2026 | Actual Questions and Answers Verified 100% Correct A permit to operate a UST system must have all of the following listed on the permit, EXCEPT: a.) The state UST identification number(s) b.) Name of the tank manufacturer and tank capacity c.) Permit expiration date d.) Monitoring requirements - ANSWER - b.) Name of the tank manufacturer and tank capacity CCR Title 23, Sec 2712(c) All underground p ressurized product piping shall have an automatic line leak detector capable of detecting a 3 - gallon per hour leak rate installed by______________. a.) July 1, 2003 b.) November 9, 2004 c.) July 1, 2004 d.) July 1, 1987 - ANSWER - b.) November 9, 2004 CCR Title 23, Sec 2636(f)(3) A temporary closure is appropriate for which of the following: a.) The UST system is empty and will be removed from service indefinitely b.) The UST system has ceased to store hazardous materials but will be used within the nex t 12 consecutive months

Read page 2 as text

c.) The UST system is unable to meet compliance requirements and will be removed d.) The UST system has been red - tagged - ANSWER - b.) The UST system has ceased to store hazardous materials but will be used within the next 12 consecu tive months CCR Title 23, Sec 2671 & 2670 A local agency determines that a UST facility within the last year had compliance issues. Prior to issuing a new permit or renewal to operate an UST the local agency shall: a.) Ask the state to assist in a join t inspection b.) Request the owner/operator to submit a "Return to Compliance" form. c.) Refer to a District Attorney Investigator d.) Inspect the facility and determine compliance - ANSWER - d.) Inspect the facility and determine compliance CCR Title 23, Sec 2712(c) Spill containers must be tested no less than _______________ to demonstrate that it is capable of containing the hazardous substances until it is detected and cleaned up. a.) Every 6 months b.) Every 36 months c.) Every 12 months d.) At the time of install or replacement - ANSWER - c.) Every 12 months H&SC, Sec 25284.2 All the following components require third party certification, except: a.) Automatic tank gauging systems b.) Statistical inventory reconciliation methods

Read page 3 as text

c.) Spill Contai nment lids d.) Liquid phase out - of - tank products - ANSWER - c.) Spill Containment lids The exterior surface of an underground storage tank must bear a marking or label which shows the following information, except: a.) Design pressure in psig b.) Useable capacity in gallons. c.) Width of the interstitial space d.) Identity of manufacturer - ANSWER - c.) Width of the interstitial space CCR Title 23, Sec 2631(b) Which of the following is not a confined space: a.) A really deep turbine sump b.) A space no t designed for continuous employee occupancy c.) An area with limited access d.) An area with limited ventilation - ANSWER - d.) An area with limited ventilation CCR Title 8, Sec 5157(b) Records for UST construction, repairs, lining, and upgrades must be kept for: a.) 3 years b.) 10 years c.) 5 years d.) The life of the tank - ANSWER - d.) The life of the tank CCR Title 23, Sec 2712(b) Under - dispenser containment was required at the time of installation for all UST systems installed after _____________ ____.

70 more pages after this

You’ve read 3 of 73. Unlock once and it stays in your library — and if the rest doesn’t match what you just read, you get a refund.

$10.00

Yours permanently