Preview Extract
Chapter 02: The X-ray Beam
Fauber: Radiographic Imaging and Exposure, 5th Edition
MULTIPLE CHOICE
1. The _____ is the portion of the x-ray tube that contains the filament.
a. cathode
b. anode
c. rotor
d. rotating disk
ANS: A
The filament, the source of electrons during x-ray production, is located in the cathode.
REF: p.16
2. The cathode filament is made of:
a. tungsten.
b. rhenium.
c. molybdenum.
d. lead.
e. nickel.
ANS: A
The cathode filament is made of tungsten.
REF: p.16
3. The focusing cup:
a. surrounds the anode.
b. has a positive charge.
c. has a negative charge.
d. focuses the x-ray beam.
ANS: C
The focusing cup, surrounding the filament on three sides, has a negative charge, keeping
the negatively charged electrons focused.
REF: p.16
4. In a dual-focus tube, how many filaments are energized at any one time during x-ray
production?
a. One
b. Two
c. Four
d. An infinite number
ANS: A
Only one filament is energized at any one time during x-ray production.
REF: p.16
5. The focusing cup is made of:
a. tungsten.
b. rhenium.
c. molybdenum.
d. lead.
e. nickel.
ANS: E
The focusing cup is made of nickel.
REF: p.16
6. _____ is the phenomenon that occurs around the filament during thermionic emission and
prevents the further escape of electrons from the filament.
a. Saturation current
b. Space charge effect
c. mA rectification
d. Line focus principle
ANS: B
The space charge effect limits the number of electrons in the space charge by preventing
additional electrons from being boiled off the filament.
REF: p.24
7. The positive side of the x-ray tube is the:
a. anode.
b. cathode.
c. window.
d. stream of electrons.
ANS: A
The anode is the positive side of the x-ray tube, and the cathode is the negative.
REF: p.17
8. The maximum speed the rotating anode will typically achieve is _____ rpm.
a. 3200
b. 5000
c. 10,000
d. 20,000
ANS: C
Rotating anodes rotate at a set speed ranging from 3000 to 10,000 revolutions per minute
(rpm).
REF: p.17
9. What is the base material of the anode disk?
a. Molybdenum
b. Tungsten
c.
d.
e.
f.
Rhenium
Graphite
A and B
A and D
ANS: F
The base of the rotating anode disk is made of molybdenum with a graphite layer.
REF: p.17
10. What is the name of the fixed physical area on the anode target that is struck by the
electron stream?
a. Focal spot
b. Focal point
c. Focal range
d. Any of the above
ANS: A
The focal spot is the fixed physical area on the focal track of the anode target where
electrons strike.
REF: p.18
11. What is the name of the device in a rotating anode x-ray tube that turns the rotor?
a. Stator
b. Rotor
c. Focusing cup
d. Rheostat
ANS: A
Located outside the envelope of the x-ray tube, the stator is an electric motor that turns the
rotor.
REF: p.18
12. Effective compensation for the anode heel effect would involve positioning:
a. the thinnest portion of the part under the anode.
b. the thickest portion of the part under the anode.
c. the thinnest portion of the part under the cathode.
d. B and C.
ANS: A
The thinnest portion of a part should be placed under the anode, because the more intense
x-rays are emitted toward the cathode end of the tube, where the thickest part should be
placed.
REF: p.34
13. What is an acceptable level of leakage from the tube housing?
a. 100 mR per hour, measured 6 feet away
b. 10 mR per hour, measured 1 foot away
c. 1000 R per hour, measured at a distance of 4 meters
d. 100 mR per hour, measured at a distance of 1 meter
ANS: D
The maximum amount of leakage radiation from an x-ray tube is 100 mR per hour when
measured at a distance of 1 meter.
REF: p.20
14. Which of the following could be defined as the production of an x-ray photon by the
electrostatic attraction between the incident electron and the nucleus of the tungsten atom?
a. Photoelectric interaction
b. Bremsstrahlung interaction
c. Characteristic interaction
d. Pair production interaction
ANS: B
Production of an x-ray photon as a result of a slowing down of the incoming electron due
to the electrostatic force of the nucleus is due to a bremsstrahlung interaction.
REF: p.20
15. Which of the following could be defined as the production of an x-ray photon by a
collision between the incident electron and a K-shell electron of the tungsten atom?
a. Photoelectric interaction
b. Bremsstrahlung interaction
c. Characteristic interaction
d. Pair production interaction
ANS: C
Characteristic interactions involve the incident electron colliding with a K-shell electron
and ejecting it from orbit. X-rays are produced as a result.
REF: p.21
16. _____ is the boiling off of electrons from the filament when current is applied.
a. Saturation emission
b. Thermionic emission
c. Filament transport
d. Proton emission
ANS: B
Thermionic emission is the emission of electrons (ion) as a result of heat (therm). The
heating of the filament is due to the application of current.
REF: p.23
17. The actual flow of electrons from cathode to anode within the x-ray tube is known as:
a. tube current.
b. filament current.
c. anode current.
d. A and C.
ANS: A
The tube current is the flow of electrons from cathode to anode within the tube.
REF: p.24
18. mA is a measure of _____ that flows from cathode to anode.
a. filament current
b. tube current
c. space charge
d. thermionic emission
ANS: B
mA or milliampere, is the unit of measure for the amount of current flowing from cathode
to anode within the x-ray tube.
REF: p.24
19. Increasing the kVp will do which of the following?
a. Decrease the tube current.
b. Increase the speed of the electrons.
c. Increase the penetrability of the beam.
d. A and C.
e. B and C.
ANS: E
Increasing the kilovoltage (kVp) increases the speed of the electrons traveling between
cathode and anode and results in an x-ray beam with greater penetrability.
REF: p.27
20. The amount the voltage varies during an x-ray exposure is known as:
a. kVp.
b. voltage ripple.
c. mA.
d. tube current.
ANS: B
The amount of variation of the voltage during an x-ray exposure is voltage ripple; it can
vary from 100% to less than 1%, depending on the type of generator being used.
REF: p.28
21. What focal spot size is measured directly under the anode target?
a. Actual focal spot
b. Target focal spot
c. Filament focal spot
d. Effective focal spot
ANS: D
Based on the line focus principle, the effective focal spot size refers to the measurement of
the focal spot from a point directly below the target.
REF: p.32
22. Filtration of the x-ray beam results in:
a. increased beam quality.
b. increased beam quantity.
c. lower average energy photons.
d. A and C.
ANS: A
Beam filtration results in removing lower-energy x-ray photons, resulting in an x-ray beam
with fewer photons but with a higher average energy.
REF: p.36
23. Which of the following is not classified as inherent filtration?
a. The oil in the transformer
b. The collimator mirror
c. The tube envelope
d. The oil surrounding the tube
ANS: A
The oil in the transformer is not in the path of the x-ray beam, so it has no role in filtering
the beam.
REF: p.35
24. The amount of filtration required to reduce the exposure of the beam to half of its original
intensity is defined as:
a. wedge filtration.
b. HVL.
c. mAs compensator.
d. TVL.
ANS: B
HVL, or half value layer, is the amount of filtration needed to reduce the intensity of the
x-ray beam to half of its original.
REF: p.36
25. Which of the following types of filtration produce a more uniform exposure to the image
receptor?
a. Compensating
b. Half-value
c. Inherent
d. Spatial
ANS: A
Compensating filters are added filters that alter the beam intensity so images of
nonuniform anatomic structures have more uniform brightness/density.
REF: p.36
26. In order to produce x-rays, electrons must be:
a.
b.
c.
d.
suddenly decelerated.
accelerated.
liberated from the cathode filament.
all of the above.
ANS: D
Electrons must be liberated from the cathode filament (thermionic emission), accelerated,
and then decelerated very suddenly in order to produce x-rays.
REF: p.16
27. The device that nearly surrounds the filament is the:
a. rotor.
b. focusing cup.
c. stator.
d. anode.
ANS: B
The focusing cup surrounds the filament with the exception of the side open to the anode.
REF: p.16
28. A dual-focus tube has two:
a. cathode filaments.
b. anodes.
c. tubes.
d. none of the above.
ANS: A
A dual-focus x-ray tube has two cathode filaments: a large and a small one.
REF: p.16
29. The rotating target track is primarily made of:
a. rhenium.
b. nickel.
c. tungsten.
d. copper.
ANS: C
The target track of a rotating anode is made up primarily of tungsten.
REF: p.17
30. The target angle of rotating targets typically ranges from:
a. 1ยฐ to 5ยฐ.
b. 5ยฐ to 20ยฐ.
c. 30ยฐ to 50ยฐ.
d. 50ยฐ to 70ยฐ.
ANS: B
Rotating anode target angles usually range from 5ยฐ to 20ยฐ.
REF: p.17
31. Tungsten has a ________ atomic number and a _________ melting point.
a. low; low
b. low; high
c. high; low
d. high; high
ANS: D
Tungsten has a high atomic number and a high melting point.
REF: p.17
32. The part of the x-ray tube that is connected to the target and causes it to turn is the:
a. filament.
b. rotor.
c. stator.
d. base.
ANS: B
The rotor is physically connected to the target and causes it to turn.
REF: p.18
33. The advantage to having a focal track is that:
a. the focal spot will be smaller.
b. the focal spot will be larger.
c. lower exposure factors can be used.
d. higher exposure factors can be used.
ANS: D
When the stream of electrons constantly has a new area of the target to hit, the result is
that higher exposure factors can be used.
REF: p.18
34. _________________ envelopes are more commonly used in todayโs x-ray tubes.
a. Glass
b. Paper
c. Metal
d. Lead
ANS: C
Metal envelopes are more commonly found in todayโs x-ray tube, replacing glass
envelopes.
REF: p.19
35. As compared to glass, which of the following is an advantage to having a metal envelope
x-ray tube?
a. Decrease in off-focus radiation
b. Increase in off-focus radiation
c. Increased deposits of tungsten on the inside surface of the envelope
d. A and C
ANS: A
The metal x-ray tube envelope results in less off-focus radiation being produced.
REF: p.20
36. Inside the x-ray tube envelope you will find:
a. oil.
b. air.
c. A and B.
d. none of the above.
ANS: D
The x-ray tube envelope has been evacuated, leaving a vacuum present.
REF: p.20
37. The speed the electrons inside the x-ray tube travel is:
a. the speed of light.
b. approximately one half the speed of light.
c. dependent on the mAs set.
d. dependent on the exposure time set.
ANS: B
The electrons in the tube current travel at approximately one half the speed of light.
REF: p.20
38. Diagnostic x-ray exposures range from:
a. 15 to 40 kVp.
b. 20 to 65 kVp.
c. 30 to 150 kVp.
d. 60 to 225 kVp.
ANS: C
The kVp in the diagnostic x-ray range varies from approximately 30 to 150.
REF: p.20
39. With a standard x-ray tube, ______________% of the x-ray beam produced with 65 kVp
is the result of bremsstrahlung interactions.
a. 0
b. 15
c. 85
d. 100
ANS: D
With a standard x-ray tube, 100% of the x-ray beam produced with 65 kVp is the result of
bremsstrahlung interactions. The electrons must have at least 69.5 keV to produce
characteristic radiation.
REF: p.20
40. With a standard x-ray tube, ______________% of the x-ray beam produced with 90 kVp
is the result of bremsstrahlung interactions.
a. 0
b. 15
c. 85
d. 100
ANS: C
With a standard x-ray tube, 85% of the x-ray beam produced with 90 kVp is the result of
bremsstrahlung interactions.
REF: p.20
41. With a standard x-ray tube, ______________% of the x-ray beam produced with 65 kVp
is the result of characteristic interactions.
a. 0
b. 15
c. 85
d. 100
ANS: A
With a standard x-ray tube, 0% of the x-ray beam produced with 65 kVp is the result of
characteristic interactions. The electrons must have at least 69.5 keV to produce
characteristic radiation.
REF: p.21
42. With a standard x-ray tube, ______________% of the x-ray beam produced with 90 kVp
is the result of characteristic interactions.
a. 0
b. 15
c. 85
d. 100
ANS: B
With a standard x-ray tube, 15% of the x-ray beam produced with 90 kVp is the result of
characteristic interactions.
REF: p.21
43. X-ray photon energy is measured in:
a. kVp.
b. mA.
c. angstroms.
d. keV.
ANS: D
X-ray photon energy is measured in keV.
REF: p.22
44. The wide range of energies in the x-ray beam is known as the:
a. homoenergetic spectrum.
b. x-ray emission spectrum.
c. gamma ray emission spectrum.
d. x-ray transmission spectrum.
ANS: B
The x-ray beam is polyenergetic (has many energies) and consists of a wide range of
energies known as the x-ray emission spectrum.
REF: p.22
45. The highest energy x-ray photons produced with a 100 kVp exposure will be:
a. 50 keV.
b. 75 keV.
c. 100 keV.
d. 125 keV.
ANS: C
In that the p in kVp stands for peak, the highest energy produced with a 100 kVp exposure
is 100 keV.
REF: p.22
46. When making an exposure, which of the following does not occur when just the rotor, or
prep button, is activated?
a. The anode begins to rotate.
b. Voltage is applied across the tube.
c. Current is applied to the filament.
d. A space charge is created.
ANS: B
Voltage is not applied across the tube until the exposure button has been pressed.
REF: p.24
47. Filament current is approximately:
a. 0.5 to 2 mA
b. 3 to 5 mA
c. 0.5 to 2 A
d. 3 to 5 A
ANS: D
It takes about 3 to 5 A of current passing through the filament to produce enough
thermionic emission to create a space charge.
REF: p.23
48. During x-ray production, the energy of the moving electrons is converted into:
a. kinetic energy.
b. thermal energy.
c. electromagnetic energy.
d. A and C.
e. B and C.
ANS: E
The kinetic energy of the electrons is converted into thermal (heat) and electromagnetic
(x-ray) energies.
REF: p.16
49. The quality of the x-ray beam indicates:
a. the number of photons.
b. the ability of the photons to penetrate.
c. the quantity of radiation.
d. whether or not the photons were made well.
ANS: B
X-ray beam quality refers to the penetrability of the photons.
REF: p.26
50. Doubling mA results in:
a. doubling the tube current.
b. doubling the quantity of x-ray photons.
c. doubling the thermionic emission.
d. all of the above.
ANS: D
Doubling the mA results in twice the thermionic emission, twice the tube current, and
twice the number of x-ray photons produced.
REF: p.30
51. Decreasing the exposure time results in:
a. fewer x-ray photons.
b. more x-ray photons.
c. higher photon energy.
d. lower photon energy.
ANS: A
Fewer x-ray photons are produced when the exposure time is shortened.
REF: p.30
52. How much is the mAs when 400 mA and 100 ms are used?
a. 4 mAs
b. 40 mAs
c. 400 mAs
d. 4000 mAs
ANS: B
Since mAs is mA ๏ด exposure time, 400 mA ๏ด 0.100 s is equal to 40 mAs.
REF: p.30
53. When electrons strike the anode target, their kinetic energy is converted into ___% heat
and ___% x-rays:
a. 1; 99
b. 99; 1
c. 0; 100
d. 100; 0
e. 50; 50
ANS: B
Most of the electron kinetic energy in the tube current (>99%) is converted into heat,
whereas less than 1% of it is converted into x-rays.
REF: p.24
54. The larger the anode angle, the:
a. larger the actual focal spot.
b. smaller the actual focal spot.
c. larger the effective focal spot.
d. smaller the effective focal spot.
ANS: C
Based on the line focus principle, the larger the anode angle, the larger the effective focal
spot.
REF: p.33
55. Due to the anode heel effect, the differences in intensities between the ends of the x-ray
field can be as much as:
a. 10%.
b. 25%.
c. 45%.
d. 60%.
ANS: C
The intensities between the anode and cathode ends of the x-ray field can vary as much as
45% due to the anode heel effect.
REF: p.34
56. Added tube filtration is typically made of:
a. lead.
b. tungsten.
c. glass.
d. aluminum.
ANS: D
Added tube filtration is usually made of aluminum.
REF: p.35
57. X-ray tubes operating above 70 kVp must have total filtration of at least _________ of
aluminum, or its equivalent.
a. 0.5 mm
b. 1 mm
c. 2 mm
d. 2.5 mm
ANS: D
X-ray tubes operating above 70 kVp must have total filtration of at least 2.5 mm of
aluminum, or its equivalent.
REF: p.35
58. As kVp increases, beam penetrability ___________.
a. increases
b. decreases
c. stays the same
ANS: A
As kVp increases, beam penetrability increases.
REF: p.27
59. The amount of heat produced from any given exposure is called a:
a. heat unit.
b. three-phase generator.
c. focal track.
d. Hounsfield unit.
ANS: A
A heat unit is the amount of heat produced by any given x-ray exposure.
REF: p.37
60. How many HU are produced when using a three-phase x-ray unit, 400 mA, 200 ms, and
70 kVp?
a. 5600 HU
b. 7560 HU
c. 5,600,000 HU
d. 7,560,000 HU
ANS: B
Heat units for a three-phase unit are equal to the kVp ๏ด mA ๏ด exposure time ๏ด 1.35, which
in this case equals 400 ๏ด 0.2 ๏ด 70 ๏ด 1.35, or 7560 HU.
REF: p.37
61. Setting identical exposure factors, which type of x-ray unit will produce the greatest heat?
a. Single phase
b. Double phase
c. Three phase
d. High frequency
ANS: D
A high-frequency x-ray generator will produce the greatest heat.
REF: p.37
62. In order to produce 12 mAs, how long should the exposure time be when using 600 mA?
a. 0.002 s
b. 0.02 s
c. 0.2 s
d. 2 s
ANS: B
Since mAs is equal to mA ๏ด exposure time, exposure time is equal to the mAs divided by
the mA. In this example that would be 12 mAs divided by 600 mA or 0.02 s.
REF: p.31
63. Which of the following practices will extend the life of the x-ray tube?
1. Use low mA and longer exposure time.
2. Warm up the tube as appropriate.
3. Hold down the rotor button for a long time, to keep the tube warmed up.
a. 1 and 2 only
b. 1 and 3 only
c. 2 and 3 only
d. 1, 2, and 3
ANS: A
In order to have the tube last longer, it is recommended that lower mA, longer exposure
time, and tube warm-up as appropriate be practiced. The rotor button should be depressed
for as little time as possible.
REF: p.39
TRUE/FALSE
1. When an electron from the L-shell of the tungsten atom is ejected from its orbit by a
projectile electron, high-energy x-ray photons are produced.
ANS: F
Very low-energy x-rays are produced when an L-shell electron is ejected from its orbit.
REF: p.21
2. The x-ray beam produced with 120 kVp will consist primarily of x-rays produced by
bremsstrahlung interactions.
ANS: T
Approximately 85% of the x-ray beam produced at 120 kVp will consist of x-rays
produced by bremsstrahlung interactions.
REF: p.20
3. Electrons can flow from cathode to anode or from anode to cathode during the x-ray
exposure.
ANS: F
Electrons can only flow from cathode to anode during x-ray production.
REF: p.24
Document Preview (16 of 147 Pages)
User generated content is uploaded by users for the purposes of learning and should be used following SchloarOn's honor code & terms of service.
You are viewing preview pages of the document. Purchase to get full access instantly.
-37%
Test Bank For Radiographic Imaging and Exposure, 5th Edition
$18.99 $29.99Save:$11.00(37%)
24/7 Live Chat
Instant Download
100% Confidential
Store
Benjamin Harris
0 (0 Reviews)
Best Selling
The World Of Customer Service, 3rd Edition Test Bank
$18.99 $29.99Save:$11.00(37%)
Chemistry: Principles And Reactions, 7th Edition Test Bank
$18.99 $29.99Save:$11.00(37%)
2023-2024 ATI Pediatrics Proctored Exam with Answers (139 Solved Questions)
$18.99 $29.99Save:$11.00(37%)
Solution Manual for Designing the User Interface: Strategies for Effective Human-Computer Interaction, 6th Edition
$18.99 $29.99Save:$11.00(37%)
Data Structures and Other Objects Using C++ 4th Edition Solution Manual
$18.99 $29.99Save:$11.00(37%)
Test Bank for Strategies For Reading Assessment And Instruction: Helping Every Child Succeed, 6th Edition
$18.99 $29.99Save:$11.00(37%)