Test Bank for Comprehensive Radiographic Pathology, 6th Edition
Preview Extract
Chapter 02: Specialized Imaging Techniques
Eisenberg: Comprehensive Radiographic Pathology, 6th Edition
MULTIPLE CHOICE
1. The first modality capable of producing images without the use of ionizing radiation was
a. ultrasound
b. magnetic resonance imaging
c. nuclear medicine
d. computerized tomography
ANS: A
The first of these new modalities was ultrasound, which was capable of producing images
without the use of ionizing radiation.
REF: Page 15
2. Which of the following was the first modality to provide sectional anatomy images with
increased visibility of soft-tissue structures?
a. Conventional tomography.
b. Computed tomography.
c. Positron emission tomography.
d. Magnetic resonance imaging.
ANS: B
In the early to mid-1970s, computed axial tomography (now known as CT) provided
revolutionary new images as a slice of anatomy.
REF: Page 20
3. With the integration of strong magnets and radio frequencies, high resolution soft-tissue
imaging in multiple planes became available with
a. nuclear medicine
b. single-photon emission computed tomography
c. computed tomography
d. magnetic resonance imaging
ANS: D
Scientists integrated the use of strong magnets and radio frequencies to provide another mode
of producing images without the use of ionizing radiation โ nuclear magnetic resonance (now
known as MRI). Magnetic resonance imaging offers clinicians images with high soft-tissue
resolution and the ability to visualize structural and functional tissue.
REF: Pages 15-16
4. Single-photon emission computed tomography took nuclear medicine imaging concepts and
added the use of
a. new pharmaceuticals
b. new pulsing sequences
c. gamma camera movement
d. stronger frequency transducers
ANS: C
Nuclear medicine expanded its role by adding movement and a computer that allowed more
than anterior and posterior projections, resulting in the development of single-photon emission
computed tomography (SPECT).
REF: Page 16
5. Which of the following uses gamma-emitting radionuclides to produce images?
a. X-ray images.
b. Nuclear medicine images.
c. PET images.
d. Sonography images.
ANS: B
Gamma-emitting radionuclides are detected by the gamma camera to produce an image.
REF: Page 28
6. Molecular imaging advancements using a positron-emitting radiopharmaceutical is
a. SPECT
b. CAT
c. MRI
d. PET
ANS: D
The creation of a positron-emitting radionuclide resulted in the newest modality โ positron
emission tomography (PET).
REF: Page 16
7. The superimposition of images from two different digital modalities produces images
a. of anatomic and physiologic perspectives
b. using software for image integration
c. from hybrid equipment, such as PET-CT
d. all of the above
ANS: D
Imaging modalities with special software can now be integrated to create a fused image
(superimposition of two different modalities). PET-CT is the most prominent hybrid
equipment available today.
REF: Page 16
8. The complexity of technology requires the radiographer to
a. have a more specific skill set
b. have an extensive knowledge of anatomy
c. have computer networking classes
d. A and B
ANS: D
Complex technology requires the radiographer to have a broader and more specific skill set to
produce quality images.
REF: Page 15
9. Which of the following specialized imaging techniques provides cross-sectional images at a
low cost, is readily available, and has the ability to differentiate cystic, solid, and complex
tissue?
a. Sonography.
b. CT.
c. MRI.
d. PET.
ANS: A
Ultrasound (sonography) is a widely accepted cross-sectional imaging technique because of
its low cost, availability, and ability to differentiate cystic (gallbladder), solid (liver), and
complex (liver tumor) tissue.
REF: Page 17
10. In ultrasound the high-frequency sound waves are produced by
a. sound waves emanating from the body
b. electrical stimulation of a specialized crystal
c. magnets and pulse radiofrequencies
d. radiopharmaceuticals
ANS: B
Ultrasound relies on high-frequency sound waves produced by electrical stimulation of a
specialized crystal to produce an image.
REF: Page 17
11. Reflections in ultrasound produced by tissue interaction are called
a. isoechoic
b. echoes
c. pulses
d. frequencies
ANS: B
The transducer records the tiny changes of the signalโs pitch and direction. A water-tissue
interface can produce strong reflections (echoes), whereas a solid tissue mass that contains
small differences in composition can cause weak reflections.
REF: Page 17
12. Fluid-filled structures transmitting sound waves easily and appearing as a dark region on the
image are _____ tissue.
a. hyperechoic
b. hypoechoic
c. anechoic
d. isoechoic
ANS: C
Anechoic tissue or structures (which are echo free or lacking a signal) transmit sound waves
easily and appear as the dark region on the image.
REF: Page 17
13. The major advantage of ultrasound is
a. no adverse effects on human tissue
b. ability to image anatomy in cross-section
c. ionizing radiation is used to produce an image
d. only low energy gamma radiation is used to produce an image
ANS: A
The major advantage of ultrasound is its safety.
REF: Page 18
14. To produce quantitative data in ultrasound, the equipment must
a. integrate real-time imaging with sono CT
b. include harmonic technology
c. fuse conventional real-time with Doppler imaging
d. have a multifrequency transducer
ANS: C
The color-flow duplex system, in which conventional real-time imaging is integrated with
Doppler imaging (to produce quantitative data).
REF: Page 18
15. To demonstrate stenoses, blood clots, plaques, and emboli requires
a. a multifrequency transducer
b. a color-flow duplex system
c. sono CT real-time compound imaging
d. harmonic imaging
ANS: B
Vascular or color-flow Doppler studies assess the patency of major blood vessels,
demonstrating obstructions (stenoses), blood clots, plaques, and emboli.
REF: Page 18
16. Using a narrow x-ray beam and scanning from multiple angles, the amount of radiation
absorbed in tissue is represented by
a. a relative linear attenuation coefficient
b. data for computer reconstruction
c. a gray scale on the computer monitor
d. all of the above
ANS: D
Scanning a slice of tissue from multiple angles with a narrow x-ray beam, then calculating a
relative linear attenuation coefficient (representing the amount of radiation absorbed in tissue
for the various tissue elements in the section), and finally displaying the computed
reconstruction as a gray-scale image on a television monitor is CT.
REF: Page 20
17. The attenuation of a specific tissue relative to water is the
a. CT number
b. echo coefficient
c. positron absorption
d. pulse sequence
ANS: A
The CT number reflects the attenuation of a specific tissue relative to that of water, which is
arbitrarily assigned a CT number of 0 and appears gray on the image.
REF: Page 20
18. Window width in CT controls
a. density
b. gray scale
c. midrange of densities
d. resolution
ANS: B
Window widths control gray scale โ contrast scale and window levels control brightness
(density). From the radiographerโs perspective, this means the window width determines the
number of shades of gray that will be visualized on the monitor.
REF: Page 20
19. The midpoint or center of the number of densities being viewed in a selected window on CT is
the
a.
b.
c.
d.
window width
pulse width
window level
x-ray level
ANS: C
The window level is the midpoint or center of the total number of densities being viewed in a
selected window width.
REF: Page 19
20. High-resolution CT requires the slice sections to be
a. 1.5 to 2.0 mm
b. 2 to 5 mm
c. 5 to 10 mm
d. 1 to 2 cm
ANS: A
In high-resolution CT, thin sections (1.5 to 2.0 mm slices) are used to produce a very detailed
display of lung anatomy.
REF: Page 21
21. CT scanning permitting data that can easily be reformatted to produce multiplanes (coronal
and sagittal) is accomplished by
a. high-resolution scans
b. conventional scans
c. helical scanning
d. single-scan protocols
ANS: C
Spiral (helical) scanning is the technique where continual CT scanning is performed as the
patient moves through the gantry (unlike the multiple single scans in conventional CT). This
permits much faster scanning without respiratory motion and provides data that can be easily
reformatted in coronal and sagittal planes.
REF: Page 21
22. What made CT angiography more precise and prevalent?
a. The development of 16-slice (and greater) scanners.
b. Multiplanar images produced by multifrequency transducers.
c. Three-dimensional images.
d. A and C.
ANS: D
Using volume-rendered imaging and 3-D volume rendering, the vascular system can be
viewed from all perspectives (360๏ฐ). CT angiography is more prevalent and precise as a result
of the development of 16-slice and greater scanners.
REF: Page 21
23. All of the following are post-processing techniques used in CT, except
a. maximum intensity projections
b. shaded surface rendering
c. time-of-flight technique
d. volume rendering
ANS: C
Time-of-flight is an angiographic technique used with MRI.
REF: Pages 22-23
24. The modality of choice to image the central nervous system is
a. CT
b. MRI
c. ultrasound
d. PET
ANS: B
MRI has become the modality of choice for imaging the central nervous system and spine.
REF: Page 24
25. What atomโs energy is manipulated to produce MRI images?
a. Radiofrequency (RF) pulse hydrogen.
b. Echo time (TE) carbon.
c. Relaxation time (T1/T2) nitrogen.
d. Repetition time (TR) oxygen.
ANS: A
The basic technique consists of inducing hydrogen atoms (protons) to alternate between a
high-energy state and a low-energy state by absorbing and then releasing, or transferring,
energy. This absorption of energy is accomplished by placing the anatomic part to be imaged
in a strong static magnetic field and directing an RF pulse at the area.
REF: Page 24
26. Relaxation is
a. the energy transfer of the radiofrequency pulse to tissue
b. the proton releasing energy to return to its original state
c. the listening time of the MR unit to hear an echo
d. the repetition of the energy signal
ANS: B
The protons begin to release, or transfer, their absorbed energy as they move back to a
low-energy state. This process is called relaxation, and it occurs over time.
REF: Page 24
27. By selecting different pulses, sequences, and frequencies, the MR T1-weighted image
produces images with a
a. high signal intensity (bright) water
b. high signal intensity (bright) fat, subacute hemorrhage, and contrast material
c. low signal intensity (intermediate to dark) fat
d. low signal intensity (very dark) bone and air
ANS: B
On T1-weighted images, substances causing high signal intensity (i.e., appearing bright)
include fat, subacute hemorrhage, highly proteinaceous material (e.g., mucus), slow-flowing
blood, and intravenous contrast material (e.g., gadolinium).
REF: Page 24
28. To best increase the exam specificity in MRI, the technologist must
a. use contrast enhancement
b. change relaxation time
c. change pulse sequences
d. A and C
ANS: D
The introduction of intravenous contrast materials and different types of pulse sequences are
helping increase specificity.
REF: Page 25
29. Diffusion imaging relies on _____ aiding in diagnosis of early stroke.
a. tissue diffused with contrast material
b. decreased microcirculation demonstrating less blood volume
c. random movement of water
d. A and C
ANS: C
Diffusion imaging relies on the movement of molecules and random thermal motion. (In this
instance, random movement of water is known as diffusion.)
REF: Page 25
30. Motor, sensory, and vision neurons (nervous system) can be demonstrated by
a. diffusion imaging
b. perfusion imaging
c. fat-suppressed images
d. functional MR
ANS: D
Functional MR (fMR) allows the localization of specific regions of the brain that correspond
to various functions, such as the motor, sensory, memory, vision, and language functions.
REF: Page 27
31. Ionizing radiation, which is emitted from the patient to produce images, is the modality of
a. conventional x-ray
b. ultrasound
c. nuclear medicine
d. magnetic resonance imaging
ANS: C
In nuclear medicine, the patient ingests, or is injected with, a radiopharmaceutical that emits
radiation, and an image is created from the signals radiating from the patient.
REF: Page 28
32. The patient is injected or ingests the ionizing radiation through
a. a radiopharmaceutical
b. an iodinated contrast agent
c. gadolinium
d. barium
ANS: A
The dose of radiopharmaceutical is calculated on the basis of the specific half-life and decay
rate of its attached radionuclide. The amount of ionizing radiation to the patient in a nuclear
medicine study is similar to that in a plain radiographic examination.
REF: Page 28
33. To detect the ionizing radiation being emitted from the patient to produce an image, a _____
is used.
a. Geiger counter
b. gamma camera
c. pocket dosimeter
d. dose calibrator
ANS: B
A gamma camera with a sodium iodide crystal detects the ionizing radiation emitted from the
patient.
REF: Page 28
34. To best demonstrate a physiologic map, the modality of choice is
a. MRI
b. CT
c. ultrasound
d. nuclear medicine
ANS: D
The physiologic map produced by some nuclear medicine procedures allows changes to be
detected earlier than plain radiographic images because the functional perspective makes it
more sensitive.
REF: Page 28
35. Increased radionuclide uptake produces a _____ on the image.
a. hot spot
b. blank spot
c. cold spot
d. homogeneous area
ANS: A
Abnormal nuclear medicine images demonstrate hot spots produced by an increase in the
uptake.
REF: Page 28
36. To enhance the nuclear medicine image, researchers applied the use of _____ to increase
accuracy.
a. computers and movement
b. multiple gamma cameras and movement
c. multiple digital cameras
d. A and B
ANS: D
SPECT imaging involves the movement of the gamma camera(s) rotating around the patient
and the computer software to perform the reconstruction of the image.
REF: Page 28
37. A collimator in the SPECT imaging system
a.
b.
c.
d.
contains multiple parallel channels allowing rays to pass
provides a lead plate increasing image contrast
is a device to allow rotation of the camera
allows more gamma rays to reach the camera
ANS: A
SPECT has a collimator containing multiple parallel channels to allow the rays to pass.
REF: Page 29
38. The greatest difference in PET and SPECT is the type of
a. ionizing radiation emitted by radiopharmaceuticals
b. camera used to detect the ionizing radiation
c. physiologic map produced
d. computer image produced
ANS: A
In positron emission tomography (PET), as in nuclear medicine procedures, a radionuclide
tracer is used to produce images. However, here the radiopharmaceutical is different because
it decays by positron emission.
REF: Pages 28-29
39. Epileptic foci and Alzheimerโs disease are best demonstrated by
a. SPECT
b. CT
c. MRI
d. PET
ANS: D
PET can be used to evaluate for stroke and to identify epileptic foci for surgical intervention.
Brain disorders that can be demonstrated by PET imaging include Parkinsonโs disease,
schizophrenia, Huntingtonโs disease, and Alzheimerโs disease.
REF: Page 31
40. Which imaging technique analyzes the chemical composition of tissues in vivo?
a. CTA
b. MRA
c. fMRI
d. MR spectroscopy
ANS: D
The development of magnetic resonance spectroscopy (MRS) has made it possible to analyze
the chemical composition of tissues in vivo.
REF: Page 25
MATCHING
Match the following terms related to specialty imaging technologies.
a. Gamma camera movement and computer enhancement
b.
c.
d.
e.
f.
g.
h.
Hybrid equipment producing two modality images simultaneously
Modality of choice for examinations of children and pregnant women
Radiofrequency pulses used to excite protons in the atoms
Radiopharmaceutical emitting gamma radiation to produce an image
Scanning a slice of tissue from multiple angles with a narrow x-ray beam
Software specially designed to overlay multidimensional computed data
Uses a decaying radiopharmaceutical emitting a positron
1.
2.
3.
4.
5.
6.
7.
8.
Computed tomography
Direct fusion imaging
Integrated imaging
Magnetic resonance imaging
Nuclear medicine
PET
SPECT
Ultrasound
1.
2.
3.
4.
5.
6.
7.
8.
ANS: F
ANS: B
ANS: G
ANS: D
ANS: E
ANS: H
ANS: A
ANS: C
REF:
REF:
REF:
REF:
REF:
REF:
REF:
REF:
Page 21
Page 32
Page 32
Page 24
Page 28
Pages 29-30
Pages 28-29
Page 17
Match the following terms related to ultrasound.
a. Echo free appearing as a dark region on the image
b. Reflections from body structures
c. Structure exhibits a relatively strong reflection appearing light gray to white
d. Tissue producing weak reflections that appear gray on the image
e. Two structures producing the same reflection
9.
10.
11.
12.
13.
Anechoic
Echoes
Echogenic
Hypoechoic
Isoechoic
9.
10.
11.
12.
13.
ANS: A
ANS: B
ANS: C
ANS: D
ANS: E
REF:
REF:
REF:
REF:
REF:
Page 17
Page 17
Page 17
Page 17
Page 17
Match the following terms related to computed tomography.
a. Ability to collect data from multiple sections per rotation
b. Attenuation of a specific tissue relative to water
c. Calculation of data collected from multiple angles using a narrow x-ray beam
d.
e.
f.
g.
Continuous scanning while the patient moves through the gantry
Contrast scale to be demonstrated on computer monitor
Midpoint selected of densities to be viewed on the computer monitor
Single scans that are integrated to produce multiplanar images
14.
15.
16.
17.
18.
19.
20.
Conventional scanning
CT number
Helical scanning
Multidetection scanning
Relative linear attenuation coefficient
Window level
Window width
14.
15.
16.
17.
18.
19.
20.
ANS: G
ANS: B
ANS: D
ANS: A
ANS: C
ANS: F
ANS: E
REF:
REF:
REF:
REF:
REF:
REF:
REF:
Page 21
Page 20
Page 21
Page 21
Page 20
Page 20
Page 20
Match the following terms related to nuclear medicine.
a. Annihilation produces two high-energy photons in opposite directions
b. Distribution of radionuclide representing the organ or system
c. Drug or chemical emitting radiation
d. Interaction of gamma rays with the sodium iodide crystal to produce light
e. Multiple gamma cameras with movement
f. Sodium iodide crystal to detect ionizing radiation emitted from patient
21.
22.
23.
24.
25.
26.
Gamma camera
Physiologic map
Positron emission tomography
Radiopharmaceutical
Scintigraphic image
Single-photon emission computed tomography
21.
22.
23.
24.
25.
26.
ANS: F
ANS: B
ANS: A
ANS: C
ANS: D
ANS: E
REF:
REF:
REF:
REF:
REF:
REF:
Page 28
Page 28
Page 29
Page 16| Page 28
Page 28
Page 16| Page 28
Document Preview (12 of 193 Pages)
User generated content is uploaded by users for the purposes of learning and should be used following SchloarOn's honor code & terms of service.
You are viewing preview pages of the document. Purchase to get full access instantly.
-37%
Test Bank for Comprehensive Radiographic Pathology, 6th Edition
$18.99 $29.99Save:$11.00(37%)
24/7 Live Chat
Instant Download
100% Confidential
Store
Evelyn Miller
0 (0 Reviews)
Best Selling
The World Of Customer Service, 3rd Edition Test Bank
$18.99 $29.99Save:$11.00(37%)
Chemistry: Principles And Reactions, 7th Edition Test Bank
$18.99 $29.99Save:$11.00(37%)
Data Structures and Other Objects Using C++ 4th Edition Solution Manual
$18.99 $29.99Save:$11.00(37%)
Solution Manual for Designing the User Interface: Strategies for Effective Human-Computer Interaction, 6th Edition
$18.99 $29.99Save:$11.00(37%)
2023-2024 ATI Pediatrics Proctored Exam with Answers (139 Solved Questions)
$18.99 $29.99Save:$11.00(37%)
Test Bank for Hospitality Facilities Management and Design, 4th Edition
$18.99 $29.99Save:$11.00(37%)